Osaka No.5 Data Center Virtual Tour

 

Get to know our data center

The following images give you an in-depth virtual tour of our Osaka No.5 data center facility.

 

ENTRANCE LOBBY
SECURITY GATE
LOADING BAY
FREIGHT ELEVATOR
SERVER ROOM
EXTERNAL COOLING PLANT
POWER RECEIVING UNITS
GENERATOR
UPS ROOM
TELECOMMUNICATIONS EQUIPMENT ROOM
ANTI-DISASTER MEASURES
OTHER FACILITIES

SITE ENTRANCE

SITE ENTRANCE

Osaka 5 Data Center stands in convenient location, only 7 minutes away from the nearest train station. Since the data center is located 6 km away from Osaka Bay and 3 km away from the closest river, natural disaster risk, including tsunamis, floods and high tides, is extremely low.

ENTRANCE LOBBY

ENTRANCE LOBBY

At the front desk, our data center staff will confirm your identity with information from web entry support system and photo ID card.

RECEPTION

RECEPTION

You will receive an IC card at reception.

SECURITY GATE

SECURITY GATE

IC card and biometric authentication are required at security gate.

BIOMETRIC AUTHENTICATION

BIOMETRIC AUTHENTICATION

Highly reliable finger vein authentication is installed.

LOADING BAY

LOADING BAY

There is a rain-free loading bay. During loading in /out, you can lock a shutter to secure your equipment.

FREIGHT ELEVATOR

FREIGHT ELEVATOR

Loading capacity: 5,000kg

FRONT CHAMBER

FRONT CHAMBER

 

SERVER ROOM

SERVER ROOM

‘Cooling Wall System,’ is installed to improve cooling efficiency and provide equal humidity in server room.

SERVER ROOM

 

SERVER ROOM

 

EXTERNAL COOLING PLANT

EXTERNAL COOLING PLANT
EXTERNAL COOLING PLANT

By using cold outdoor air, power consumption of air conditioning will be reduced.

POWER RECEIVING UNITS

POWER RECEIVING UNITS
POWER RECEIVING UNITS

There are two power receiving units laid on from two different substation to realize a reliable power supply.

GENERATOR

GENERATOR

Gas turbine engine in N+1 configuration provides uninterrupted backup power in case of an emergency.

UPS ROOM

UPS ROOM

Fully redundant UPS maintains consistent power supply for your racks.

TELECOMMUNICATIONS EQUIPMENT ROOM

TELECOMMUNICATIONS EQUIPMENT ROOM

Communications routes are laid from four directions, include connected directly to secure earthquake-proof cable tunnel, with no damage from past major earthquakes.

ANTI-DISASTER MEASURES

SEISMIC-ISOLATION DEVICE

SEISMIC-ISOLATION DEVICE

SEISMIC DAMPER

SEISMIC DAMPER

ANTI-FLOODING MEASURES

In the unlikely event that water were to reach the data center, equipment would continue to operate safely because the electric power equipment, comunication facilities, server rooms and other important facilities are located on the second floor or above, over 7m above ground level.

ANTI-EARTHQUAKE MEASURES

Piles are driven more than 50m into the hard foundation to support the building. The building's seismic-isolation devices, which lessen the impact of strong shaking by the earthquake, are installed on the post beneath the second floor. Inaddition, seismic dampers are installed to suppress the vertical shaking by epicentral earthquake.

OTHER FACILITIES

OFFICE SPACE FOR CUSTOMERS

OFFICE SPACE FOR CUSTOMERS

CUSTOMER LOUNGE

CUSTOMER LOUNGE

STAGING ROOM

STAGING ROOM

LOCKER

LOCKER

KITCHEN

KITCHEN

HELIPORT

HELIPORT